Prepare clean hands and the right equipment
Use the correct strips, a new lancet and your own lancing device. Check expiry and the manufacturer's after-opening instructions. Food residue can falsely raise readings; wiping away a first drop is not a reliable replacement for clean hands.1
Wash with soap and water, then dry fully. If an alcohol swab is used, let it dry completely; food residue still needs proper cleaning. Follow device instructions for drop size and sampling.
A practical testing sequence
Device instructions take priority over universal rules about which blood drop to use or whether extra blood can be added.146
Wash and dry your hands
Use soap and water, then dry fully. Remove any food or sugar left on your fingers.
Use the side of a fingertip
The green circle marks the side. Rotate sites and avoid forceful squeezing; do not repeatedly prick the centre pad.
Contain the used lancet safely
Place it promptly in a secure, puncture-resistant sharps container, never loose household rubbish.
These are explanatory illustrations, not photographs of a specific device. Follow your meter, strip and lancing-device instructions.
- Insert the right strip and close its container promptly.
- Use an appropriate lancing depth at the side of a fingertip; rotate sites.
- Avoid forcefully squeezing the finger.
- Apply sufficient blood as instructed; do not reuse strips.
- Record the result and put the used lancet in a secure puncture-resistant container, not loose household rubbish. Never share pens or needles.
A purpose-made sharps container is preferred. If unavailable, a temporary alternative must be heavy-duty, puncture-resistant and leak-resistant with a secure lid. Keep it away from children and pets, and ask the clinic or local health service about safe disposal. Do not use thin drinks bottles or put the container in household rubbish or recycling.
Errors that can change a result
Wet or food-contaminated fingers, damaged strips, insufficient blood, unsuitable temperatures or the wrong strip can affect results. Severe dehydration, certain blood conditions and some medicines can also interfere depending on the meter.1
During heat and humid weather, keep strips away from direct sun, hot cars and damp places. Do not apply a universal refrigerator rule or a three-to-six-month opened-container lifetime. Use the stated storage limits and discuss control-solution checks when appropriate.
Know what fasting and post-meal mean
Laboratory fasting generally means at least eight hours without calories; plain water is usually allowed. Do not stop prescribed medicines without specific instructions.234
| Timing | Clarify | Common reference for many non-pregnant adults |
|---|---|---|
| Before meals | Morning fasting or before another meal? | 80–130 mg/dL |
| After meals | Usually 1–2 hours from the first bite, as agreed | Below 180 mg/dL |
| Bedtime/overnight | Is this needed for your medicine or low-glucose risk? | Individual target; no single universal range |
Children, pregnancy, frailty, kidney disease and recurrent lows may require different targets. These are not diagnostic cutoffs for people without diabetes.
Choose checks that answer a question
Insulin, hypoglycaemia risk, illness, pregnancy and treatment changes may require more monitoring. Routine frequent checks without a purpose may add little for some stable people with type 2 diabetes.24
Paired pre- and post-meal checks or a short structured log can sometimes help. Neither a four-tests-daily schedule nor a two-days-weekly schedule is correct for everyone.
Why the laboratory and meter may differ
Sample, timing and measurement methods differ. Most modern meters report a plasma-equivalent estimate; do not assume a fixed 10–20% difference merely because the sample is capillary blood.13
Approved meters still have measurement variation. Accuracy standards are not a guarantee that every individual reading is correct. Repeated large differences or a symptom mismatch need a review of technique, strips, control solution and appropriately timed laboratory comparison. A meter alone does not diagnose diabetes.
Record context, not only numbers
Date, time, meal relationship, medicine timing, symptoms and activity notes make a log more useful. Leave an unperformed check blank rather than entering zero.24
- Bring the meter and recent records to review.
- Do not copy demonstration readings into your own diary.
- Never double treatment from an isolated number.
- Check what personal information a printout or shared file contains.
Frequently asked questions
Can I drink water before a fasting test?
Plain water is usually allowed. Tea, milk, juice and sugary drinks are different; follow the laboratory's instructions.
Does post-meal timing begin after finishing the meal?
It is usually counted from the first bite. Confirm the one- or two-hour timing requested.
Must everyone discard the first drop?
No. Clean, dry hands and device instructions matter. A second drop from an unclean finger does not guarantee accuracy.
Can a family share a lancing pen?
No, even if the lancet is changed.
Does a small laboratory difference mean my meter is useless?
Not necessarily. Compare properly and seek review for large differences or serious symptoms.
Related questions and guides
Guidelines and references
- FDA · Blood glucose meters: getting the most out of your meter
- ADA Standards of Care 2026 · Glycemic goals and hypoglycemia
- NIDDK · Diabetes tests and diagnosis
- RSSDI · Clinical Practice Recommendations for Type 2 Diabetes 2022
- CDC · Treatment of low blood sugar
- FDA · Safely using sharps at home and while travelling
Dr. Pratyush Kumar · DNB Family Medicine, Sir Ganga Ram Hospital · DFID Diabetes Fellowship, Christian Medical College, Vellore
Last medically reviewed: · General education, not an individual prescription.